Thursday, September 5, 2013

Home Owner Newsletter #7


A humble request

If you think that I did a good job inspecting your home, please mention me to anyone you know who will need a home inspector.  If there's any reason you would hesitate to recommend me, please let me know
Welcome to the Homeowner’s Newsletter!  Each month, you’ll find plenty of useful information for keeping your house in great condition so that you can enjoy it for years to come. Preserve your investment—and keep your family safe and healthy—by maintaining your home using the following tips.


Water Heaters

A water heater is an appliance that heats potable water and supplies heated water to the home’s plumbing distribution system.  Most tanks are insulated steel cylinders with an enamel coating on the inner surface. They are referred to as glass-lined tanks. The lining helps prevent corrosion.  A water heater can literally explode if it’s not installed properly. There are standards that regulate the materials, design and installation of water heaters and their related safety devices. Certification marks on them from approved agencies indicate compliance with approved standards.

Conventional residential water heaters have life expectancies that vary greatly.  The typical water heater has a lifespan of about 10 years, based on the following factors: correct installation; usage volume; construction quality; and maintenance.

Correct Installation
A water heater should generally be installed upright. Installing a water heater on its side will place structural stress on it due to inadequate support for the heater and its pipes, and may cause premature failure.  Water heaters should be installed in well-ventilated areas -- not just for fire safety requirements and nitrous-oxide buildup, but also because poor ventilation can shorten its lifespan.  A water heater should also not be placed in an area susceptible to flood damage. Water can rust out the exterior and pipes, decreasing the life expectancy and efficiency of the unit.  A water heater is best placed in an easily accessible area for maintenance.  It should also be readily visible for fire and health-hazard requirements.

Usage
The life expectancy of the water heater depends a great deal on the volume of water used. Using large quantities of water means that the water heater will have to work harder to heat the water. In addition, the greater the volume of water, the greater the corrosive effect of the water will be on the tank materials, pipes, etc.

Construction Quality 
As with most household systems and components, you get what you pay for in a water heater. Cheaper models will generally have a shorter lifespan, while more expensive models will generally last longer. A good indication of a water heater’s construction quality is its warranty.  Longer warranties naturally imply sound construction. According to a 2007 Consumer Report that deconstructed 18 different models of water heaters, it was determined that models with longer warranties were of superior manufacturing quality, with nine- and 12-year models typically having larger or higher-wattage heating elements, as well as thicker insulation. Models with larger heating elements have a much better resistance to mineral buildup or scum.

Pay attention to the model's features.  For example, porcelain casing provides an additional layer of protection against rusting, and a greater level of heat insulation. Some models come with a self-cleaning feature that flushes the pipes of mineral deposit buildup, which can affect the unit's lifespan.  Models with larger or thicker anodes are better-equipped to fight corrosion.

Maintenance and Parts Replacement
The hardness of the water is another consideration when looking at estimating the lifespan of a water heater.  In areas where there is a higher mineral content to the water, water heaters have shorter a lifespan than in other areas, as mineral buildup reduces the units' efficiency. Even in areas where the water is softer, however, some mineral deposition is bound to occur.  A way to counteract this mineral buildup is to periodically flush the water heater system, which not only removes some of the buildup, but, in tank systems, the process heats the water in the tank. Higher-end models typically come equipped with a self-flushing feature.  In models for which manual flushing is required, it is important not to damage the water heater valve, which is usually made of plastic and is easy to break.

Although an older model may appear to be well-maintained, a question arises:  Is the maintenance worth it? Warranties often exclude labor costs, so a good rule to follow is that if the total repair cost per year is greater than 10% of the cost of buying and installing a new water heater, it is probably not worth replacing any damaged parts.

 

Toilets & Bidets

A water closet in the U.S. is commonly referred to as a toilet.  The term “water closet” originates from the time when plumbing was brought indoors, and defecation took place in a small, closet-size room with a pot.

Toilet Styles   
There are three styles of water closets: close-coupled, one-piece, and flushometer valve.  The most common is the close-coupled water closet, which has a bowl and separate gravity-type tank or flushometer tank that is supported by the bowl.  A one-piece water closet is constructed with the gravity-type tank or flushometer tank and bowl as one integral unit.  A flushometer-valve water closet is a bowl with a flushometer valve.  Water closet bowls come in six styles: blow-out, siphon jet, reverse trap, wash-down, siphon vortex, and siphon wash.
Toilet Measurements
A water closet has a water consumption limit of a maximum average of 1.6 gallons of water per flush. The general bowl rim height above the floor is between 14 and 15 inches.  Other rim heights may be needed for water closets used by children (10 inches), and the elderly and persons with physical disabilities (18 inches).  Elongated water closet bowls are required for public or employee use but are often installed in homes.  An elongated bowl is 2 inches longer than a regular bowl. 

Defects at Toilets
The water closet (toilet) may have a clogged drain.  While flushing the toilet, watch the flush performance, and use toilet paper as part of this test.  There should be no excessive odors around the water closet.  Check the flooring around the toilet with your foot.  Using the side of your leg, check to see if the toilet is securely attached to the floor.  If it wobbles, the screws at the base may be loose, or the wax ring that adheres the fixture to the waste pipe may be worn or of the wrong size.  If so, it should be replaced.  Look for dampness around the bottom of the toilet base.  Toilets sometimes run continuously.  Check for a water shut-off valve.  Some toilets are mistakenly connected to the hot water system.  Tank lids are often cracked.  Any defective parts should be immediately replaced to avoid backup flooding.

Bidets
Common in much of Europe and Asia, bidets are toilet-like plumbing fixtures designed to promote posterior hygiene. They’re becoming increasingly common in North America.  Contrary to popular belief, a bidet is not an alternative to a toilet.  Its purpose is as a hygiene device following toilet use.  However, some bidets have been incorporated into toilets, especially in bathrooms that are not large enough for both fixtures.

Bidets, like toilets, are typically made from porcelain and contain a deep recess within a wide rim. They emit an arc of clean water from a nozzle that may be located beneath the rear of the rim or deep within the fixture’s cavity. Users can sit on the rim (or seat, if it has one), or straddle the fixture and face in either direction. He or she can decide which direction to face based on the water jet configuration and the part of their body that needs cleaning. Water temperature and pressure can be adjusted with knobs in order to arrive at the desired settings.

Some bidets come with built-in air dryers. Toilet paper can be used for this purpose if no dryer is available. The bidet can be rinsed after use to keep it clean.

Benefits
  • People who suffer from hemorrhoids, irritable bowel syndrome, or have recently had surgery can find relief with the more gentle water flow of a bidet.
  • As the bidet requires less operator mobility, they are easier to use for the elderly, disabled and obese.
  • Many believe that the use of bidets is more hygienic and effective than toilet paper.
Safety Precautions 
  • Users should familiarize themselves with the rate of temperature and pressure changes that occur when they adjust the controls. Sensitive regions can be burned if the user is not careful, and high water pressure can be irritating.
  • Users should know in advance the direction of the water arc and position themselves accordingly. The spray can be powerful enough to strike a person in the face.

 

Bathroom Sinks (Lavatories)


Lavatories
A lavatory is a washbasin or sink located in a bathroom or washroom.  "Lavatory" means washbasin or sink, and is derived from the Latin word lavatorium, which means washing vessel, and the French word laver, meaning "to wash." Lavatories come in a variety of shapes and sizes.  They are available in enameled cast-iron, vitreous china, stainless steel, porcelain-enameled formed steel, plastic, and non-vitreous ceramic.  They can be wall-mounted, hanger-mounted, under-mounted, pedestal, rimmed, and above-center basin types.
Countertops integrated with lavatories are constructed of a variety of materials, including ABS, PVC, gel-coated fiberglass-reinforced plastic, acrylic, polyester, and cultured marble.  Plastic vanity tops should be impregnated with fire-resistant chemicals to reduce the fuel contribution of the lavatory during a house fire or the accidental fire from a plumber's torch.  They are also made to resist the effect of a burning cigarette left unattended on the vanity top.

Lavatories should have a waste outlet of at least 1-1/4 inches in diameter.  Each lavatory must have a strainer, a pop-up stopper, a crossbar, or other mechanism to prevent items such as rings, toothbrushes and cosmetic items from dropping into the drain.

Lavatory Overflows
Former standards required lavatories to have an overflow, but that is no longer the case.  The overflow is now an option of the manufacturer.  The reason for not requiring an overflow at a lavatory is because of the lack of use of the overflow, which can cause bacterial and micro-organism growth.

Where a lavatory does have an overflow installed, the cross-sectional area of the overflow should be a minimum of 1-1/8 inches; anything larger can promote bacterial and micro-organism growth.  The overflow should be able to prevent overflowing of the sink for a minimum of five minutes when tested from the onset of water flowing into the overflow's opening.

Maintenance Tips
There are many different designs of lavatories, including artisanal styles that sit up on the vanity, rather than being dropped into a recessed cavity in the vanity or countertop.  Regardless of the style or whether it includes an overflow opening, the washbasin should be securely attached to the vanity, be free of cracks and other defects, and have gaps that are properly caulked to prevent moisture buildup, which can lead to unsanitary conditions, including mold growth.

 

Bathtub & Showers


Bathtubs
Bathtubs are made from many different types of materials, including enameled cast-iron, porcelain-enameled steel, and plastic. Plastic tubs are made from materials including ABS, PVC, fiberglass, fiberglass-reinforced plastic, acrylic, and cultured-marble acrylic. Bathtubs that are equipped with shower fixtures should be manufactured with slip-resistant surfaces. Bathtubs should have a drainage outlet (tailpiece) with a minimum diameter of 1-1/2 inches. Every tub should be equipped with a stopper. The bathtub should have an overflow outlet installed. The overflow prevents flooding if the tub is being filled while unattended, and prevents overflow of the water when a person enters a tub that is full.

Fire-Resistance
Bathtubs made of plastic are tested for fire ignition.  They are made with fire-resistant chemicals to reduce their fuel contribution in a house fire, or an accidental exposure to a plumber’s torch.

Large Bathtub Loads
Some bathtubs are so large that they can accommodate more than one person at a time.  These larger bathtubs may need special and additional structural support underneath them to adequately support the load.
A 3x4-foot bathtub may have a capacity to hold 200 gallons or more.  The weight of the bathtub, water, and occupants may total over 1 ton, considering:

                                                  200 pounds for the bathtub
                                            + 1,600 pounds of water
                                            +    350 pounds for two people
                                            = 2,150 pounds


A very large tub may cause structural problems because live-loading for a typical residential home is 40 pounds per square foot.  The live load for a 3x4-foot occupied tub may be assumed to be only 480 pounds, but may weigh over 2,000 pounds while it is in use.

Maintenance Tips
The homeowner should make sure that the tub is free of cracks, rust and other staining, and that all edges, gaps and surrounding tile are adequately caulked to ensure that moisture cannot leach behind the tile work and drywall, which can lead to leaks and structural damage behind walls that won’t be evident until the issue becomes extensive and expensive to fix.

Showers
Plastic, pre-fabricated shower units are constructed of various synthetic materials, including ABS, PVC, gel-coated fiberglass-reinforced plastic, cultured marble, cast-filled fiberglass, polyester, cultured marble acrylic, and acrylic.  These shower units are impregnated with fire-retardant chemicals to reduce the fuel contribution during a fire, and protection against an accidental burn by a plumber's torch.

The showerhead height is not typically regulated by building codes, but the head is commonly installed 70 to 80 inches above the shower floor.

Shower Water Pipes
Water-supply pipes from the shower valve to the showerhead outlet -- referred to as the shower riser pipes -- whether exposed or not, must be firmly attached to a structural component to prevent the pipes from leaking caused by stress fractures or joint failures.  Movement of the showerhead may move the riser piping, possibly causing failure of the piping.  The risers must be firmly secured. 

The common practice for installing the riser pipe is to place a drop-ear elbow at the top of the riser pipe.  The elbow has two wing connections.  They can be screwed to a structural backing board, such as a 2x4.  A pipe strap can be used instead of a drop-ear elbow.  When the riser is exposed, the manufacturer will typically provide a strap or attachment device to match the finish of the fixture and pipe.  The strap or attachment device should be firmly secured to a structural component.

Shower Outlets
The waste outlet for a shower should have minimum diameter of 1-1/2 inches.  The shower outlet should have a strainer that is at least 3 inches in diameter, with dimensional openings in the strainer of at least a 1/4-inch.  The strainer should be removable.

Shower Area
A shower compartment should have an interior cross-sectional area of at least 900 square inches.  This will allow an average-sized adult to clean the lower body while bending over.  A shower that’s any smaller would be inadequately sized.  Shower compartments should be at least 30 inches in minimum dimension.  This measurement is based on the movement of an adult body inside a shower and measured from the finished     interior dimension of the compartment, excluding fixture valves, showerheads, soap dishes and grab bars.  There are exceptions for showers having fold-down seats, and those with compartments at least 25 inches wide and 1,300 square inches in cross-sectional area.

The exception allows for a shower with one dimension being 25 inches, provided the compartment has at least 1,300 square inches of cross-sectional area.  This is useful to contractors and DIY homeowners who remove an old bathtub and install a standup shower fixture in the same space.

Shower Walls
Showers and bathtubs with installed showerheads should be finished with a non-absorbent surface that shall extend to a height of not less than 6 feet above the floor level of the room, or 70 inches above the shower floor.  It should be constructed of smooth, corrosion-resistant and non-absorbent materials to protect the structural components from moisture damage.  The gypsum or cement wallboard behind ceramic tiles of a shower wall should be water-resistant. The water-resistant material is not required in the rest of the bathroom, although it is a common practice to use water-resistant gypsum wallboard in other areas of the bathroom because of the moisture levels.

Shower Access and Egress Opening
Many injuries in a home are related to accidents in the bathtub or shower.  The minimum opening requirements for access and egress allows an adult enough room to safely step into and exit the shower area without having to twist or turn through a narrow opening.  The shower opening (or access and egress opening) should be at least 22 inches of clear and unobstructed finish-width.  The 22-inch width is based on the approximate shoulder width of an average-sized adult, and provides comfortable access to service the valves, showerheads and drain.  It allows for emergency response and rescue access, and emergency egress.

Shower Floors 
The shower floor surface must be watertight with smooth, corrosion-resistant, non-absorbent, waterproof materials.  Joints between the floor and walls of the shower must be sealed or flashed to prevent water penetration.  Ideally, there should be some type of slip-resistant floor surface.  The shower floor structure needs proper support by a smooth and structurally sound base.  The base of the shower floor should be designed to support both dead (structural) and live (people and water) loads. 

Shower pans and liners are installed under and around showers to prevent moisture intrusion from getting into the structural supports under and behind the shower enclosure.  They must meet specific standards for material, installation and size in order to support both dead and live loads.

Shower Glazing 
Glass doors enclosing the shower should be made of safety glazing.  If a window is installed in the shower, the window should be made of safety glazing to provide protection.  If a person slips or falls inside the shower, s/he may be seriously injured by broken glass if the glass is not made of safety glazing.  The safety glazing should be correctly labeled by being permanently marked in a corner, legible and visible after installation, and indoor applications should be marked “indoor use only.”

Maintenance Tips
Similar to other bathroom fixtures, the homeowner should make sure that the shower is free of cracks, rust and other staining, and that all edges, gaps and surrounding tile are adequately caulked to ensure that moisture cannot leach behind the tile work and drywall, which can lead to leaks and structural damage behind walls that won’t be evident until the issue becomes extensive and expensive to fix.  Additionally, if the glazing for the showers doors is damaged, it should be replaced, as cracked glazing can break without notice and cause serious injuries.


Regards,

Jeff L. Gollaher
Full Circle Home Inspections

Saturday, August 3, 2013

Monday, July 22, 2013

Home Maintenance Newsletter

Illustration of home

A humble request

If you think that I did a good job inspecting your home, please mention me to anyone you know who will need a home inspector.  If there's any reason you would hesitate to recommend me, please let me know
Welcome to the Homeowner’s Newsletter!  Each month, you’ll find plenty of useful information for keeping your house in great condition so that you can enjoy it for years to come. Preserve your investment—and keep your family safe and healthy—by maintaining your home using the following tips.



Indoor Air Quality Issues

Indoor air quality is generally worse than most people believe, but there are things you can do about it.

Some Quick Facts:
  • Indoor air quality can be worse than that of outdoor air.
  • Problems can arise from moisture, insects, pets, appliances, radon, materials used in household products and furnishings, smoke, and other sources.
  • Effects range from minor annoyances to major health risks.
  • Remedies include ventilation, cleaning, moisture control, inspections, and following manufacturers' directions when using appliances and products.
Many homes are built or remodeled more tightly, without regard to the factors that assure fresh and healthy indoor air circulation. Many homes today also contain furnishings, appliances and products that can affect indoor air quality.

Signs of indoor air quality problems include:
  • unusual and noticeable odors;
  • stale or stuffy air and a noticeable lack of air movement;
  • dirty or faulty central heating or air-conditioning equipment;
  • damaged flue pipes and chimneys;
  • unvented combustion air sources for fossil-fuel appliances;
  • excessive humidity;
  • the presence of molds and mildew;
  • adverse health reactions after remodeling, weatherizing, bringing in new furniture, using household and hobby products; and 
  • feeling noticeably healthier outside.
Common Sources of Air Quality Problems
Poor indoor air quality can arise from many sources. At least some of the following contaminants can be found in almost any home:
  • moisture and biological pollutants, such as molds, mildew, dust mites, animal dander, and cockroaches;
  • high humidity levels, inadequate ventilation, and poorly maintained humidifiers and air conditioners;
  • combustion products, including carbon monoxide from unvented fossil-fuel space heaters, unvented gas stoves and ovens, and back-drafting from furnaces and water heaters;
  • formaldehyde from durable-press draperies and other textiles, particleboard products, such as cabinets and furniture framing, and adhesives used in composite wood furniture and upholstery;
  • radon, which is a radioactive gas from the soil and rock beneath and around the home's foundation, groundwater wells, and some building materials;
  • household products, such as paints, solvents, air fresheners, hobby supplies, dry-cleaned clothing, aerosol sprays, adhesives, and fabric additives used in carpeting and furniture, which can release volatile organic compounds (VOCs); 
  • asbestos, which is found in most homes more than 20 years old. Sources include deteriorating, damaged and disturbed pipe insulation, fire retardant, acoustical ceiling tiles, and floor tiles;
  • lead from lead-based paint dust, which is created when removing paint by sanding, scraping or burning;
  • particulates from dust and pollen, fireplaces, wood stoves, kerosene heaters, and unvented gas space heaters; and
  • tobacco smoke, which produces particulates, combustion products and formaldehyde.

Tips for Homeowners
•       Ask about formaldehyde content before buying furniture, cabinets and draperies.
•       Promptly clean and dry water-damaged carpet, or remove it altogether.
•       Vacuum regularly, especially if you have pets, and consider using area rugs instead of wall-to-wall carpeting. Rugs are easier to remove and clean, and the floor underneath can also be easily cleaned.
•       Eliminate unwanted moisture intrusion by checking for sources (such as holes and cracks in the basement and other areas, and leaks from appliances), and by using a dehumidifier.
•       Open windows and use fans to maintain fresh air with natural and mechanical air circulation.
•        Always open the flue damper before using the fireplace.  This will also prevent carbon-monoxide poisoning.
•       If your air conditioner has a water tray, empty and clean it often during the cooling season.
•       If you smoke, smoke outdoors and away from any windows and doors.
•       Use the range vent above your stove whenever you cook.
•       Use the bathroom vent whenever you use the bathroom.
•       Don’t leave vehicles or lawn care equipment running in your garage.  Make sure the door leading from the home to the garage has a door sweep to help keep out vapors.

Your InterNACHI inspector can recommend more ways to help you maintain healthy indoor air quality for you and your family.
 

Dryer Vent Maintenance & Safety

House fires caused by dryers are far more common than are generally believed.  According to the National Fire Protection Agency, fires caused by dryers in 2005 were responsible for approximately 13,775 house fires, 418 injuries, 15 deaths, and $196 million in property damage. Most of these incidents occur in residences and are the result of improper lint cleanup and maintenance. Fortunately, these fires are very easy to prevent.

Clothes dryers evaporate the water from wet clothing by blowing hot air past them while they tumble inside a spinning drum. Heat is provided by an electrical heating element or gas burner. Some heavy garment loads can contain more than a gallon of water that will become airborne water vapor and leave the dryer and home through an exhaust duct, more commonly known as the dryer vent.

A vent that exhausts damp air to the home's exterior has a number of requirements:
•       It should be connected. The connection is usually behind the dryer but may it be under it. Look carefully to make sure it’s actually connected.
•       It should not be restricted. Dryer vents are often made from flexible plastic or metal duct, which may be easily kinked or crushed where they exit the dryer and enter the wall or floor. This is often a problem since dryers tend to be tucked away into small areas with little room to work. Vent hardware is available that is designed to turn 90 degrees in a limited space without restricting the flow of exhaust air.  Air flow restrictions are a potential fire hazard.
•       One of the reasons that restrictions pose a fire hazard is that, along with water vapor evaporated out of wet clothes, the exhaust stream carries lint – highly flammable particles of clothing made of cotton, wool and polyester. Lint can accumulate in an exhaust duct, reducing the dryer’s ability to expel heated water vapor, which then accumulates as heat energy within the machine. As the dryer overheats, a subsequent mechanical failure can trigger a spark, which can cause the lint trapped in the dryer vent to burst into flames. This condition can cause the whole house to catch fire.  Fires generally originate within the dryer but spread by escaping through the ventilation duct, incinerating trapped lint, and following its path into the home’s walls.

Problems & Tips
If your dryer vent terminates in the crawlspace or attic, it can deposit moisture there, which can encourage the growth of mold, wood decay, and other structural problems. The vent may also terminate just under the attic ventilators. This is also a defective installation. Make sure your dryer vent terminates at the exterior and away from any doors and windows so that damp, exhausted air won’t re-enter the home. Also, the end of the dryer vent should have a free-moving damper installed to keep out birds and other pests that like to build nests in this warm environment.  If you find a screen, this is a defective installation because a screen can block lint and other debris, causing it to accumulate and leading to a house fire.  If it’s safety accessible, make sure your dryer vent is unobstructed and that the damper works properly.
 

WDO & Pest Control

Wood-destroying organisms and other pests can cause serious problems in the wooden structural components of a house, and an infestation may go unnoticed until the damage is already extensive. Control measures include preventing insect entry by sealing holes and cracks, and hiring a professional to apply chemicals for remedial treatment.  The most commons types of destructive insects are termites and ants.

Termites
Subterranean termites are the most damaging insects of wood. Their presence is hard to notice, and damage usually is found before the termites are seen. You should take measures to prevent infestations, which may require hiring a pest-control service.
If you see the following signs in your house, you might have termites:
•       frass or sawdust-like droppings, which result from the termites’ tunneling activity;
•       dirt or mud-like tubes or trails on various parts of the home’s structure, such as wooden support members, plumbing pipes, etc.;
•       damaged wood members (such as window sills); and
•       swarming winged insects within the home, especially in the spring or fall.

Ants
Ants are among the most prevalent pests in households, restaurants, hospitals, offices, warehouses, and virtually all buildings where food and water can be found. While mostly harmless to humans, carpenter ants can cause considerable damage.
The following clues are evidence that your home is host to an ant infestation:
•       long trails of ants, perhaps numbering in the hundreds or thousands. Ants assemble in long trails along structural elements, such as wires and pipes, and frequently use them to enter and travel within a structure to their destination;
•       a few straggler ants, which are scouts in search of food and nesting sites;
•       holes or cracks in walls or the foundation, especially where pipes enter the building, and around windows and doors. These can provide entry points for ants and other insects.  The kitchen (where food is stored and prepared) is a particular problem area;
•       frass deposits, which result from the ants carving tunnels or galleries in the wood;
•       a distinctive rustling sound similar to the crinkling of cellophane. Ants are small but their nests are large enough to produce perceptible noise; and
•       nests in mulch and vegetation outdoors next to the foundation. Check under potted plants, patio blocks, stepping stones, in piles of rocks, lumber and firewood.

Other Pests
Snakes, spiders, bees and/or scorpions may be living in your crawlspace, and while they pose little structural danger to the house, they certainly can harm you. Rapid retreat there can be difficult, so if you’re in your crawlspace for any reason (storing items, looking for moisture intrusion or a water leak, etc.), be aware of your escape paths, and carry an extra flashlight in case the one you’re using suddenly stops working.

Your crawlspace is also the most likely area in the house where hantavirus may be found. This is partly due to the fact that rodents that carry the pathogen are attracted to areas that are undisturbed by humans. Also, crawlspaces are generally dark places that lack ultraviolet (UV) radiation, which can rapidly inactivate the virus. Exposure to hantavirus may lead to Hantavirus Cardiopulmonary Syndrome (HCS), characterized by headaches, fever, difficulty breathing and, often, death. There is no known cure, vaccine or treatment that specifically targets HCS. However, if the symptoms are recognized early, patients may benefit from oxygen therapy.

The Importance of a WDO Inspection
Regular inspections of your house are an important part of home maintenance. Inspecting for wood-destroying insects can alert you to possible infestations in the wooden structural components of your home—a serious problem that often goes undetected for a long time.  Call your InterNACHI inspector for a WDO Inspection if you suspect that your home may be infested.
Regards,

Jeff L. Gollaher
Full Circle Home Inspections

Sunday, June 23, 2013

Wednesday, May 29, 2013

Homeowner's Newsletter from Full Circle Home Inspections

A humble request

If you think that I did a good job inspecting your home, please mention me to anyone you know who will need a home inspector.  If there's any reason you would hesitate to recommend me, please let me know

Homeowner's Newsletter from Full Circle Home Inspections


Welcome to the Homeowner’s Newsletter!  Each month, you’ll find plenty of useful information for keeping your house in great condition so that you can enjoy it for years to come. Preserve your investment—and keep your family safe and healthy—by maintaining your home using the following tips.


Roof-Covering Maintenance


Although homeowners aren’t necessarily expected to climb on their roofs every season as part of regular home maintenance, there are some conditions that should be monitored to prevent roof damage and to help you get the longest life out of your roof-covering materials.  Certain types of damage can lead to water and pest intrusion, structural deterioration, and the escape costly energy.

Weathering 
Hail and storm damage, known as weathering, can weaken a roof’s surface even if you haven’t lost any shingles/shakes/slates following a storm.  It’s the most common source of environmental damage for roofs.  Strong, sustained winds can cause uplift to the edges of shingles and shakes, which can weaken their points of attachment and allow rainwater and melting snow to reach the roof’s underlayment.  Wind can also send projectiles through the air, which can damage every surface of the home’s exterior, including the roof.  You should always inspect your roof after a heavy weather event, as far as it is practical to do so without taking any undue risks, to check whether you have lost any roof-covering materials, or if any parts look particularly weathered or damaged.  A small fix now could prevent costly repairs later.

Tree Damage 
Tree damage results from wind-blown tree branches scraping against shingles and from the impact of falling branches blown by wind and/or because the nearby tree has dead branches that eventually break off and fall.  Branches that overhang the roof should always be cut back to avoid damage from both abrasion and impact, and to prevent the accumulation of leaf debris on the roof, its valleys, and in the gutters, which will interfere with proper drainage and lead to pooling of rainwater and snowmelt.  Of course, it’s especially important to make sure that tree limbs near the home’s roof and exterior are a safe distance away from utility and power lines.  Tree-trimming is a type of homeowner maintenance task should be undertaken by qualified professionals, as it can lead to accidentally cutting off the service or power from an overhead line, being electrocuted by an energized line, being struck by an unsecured tree branch, falling off the roof or a ladder, and any number of similar mishaps that the homeowner is not trained to anticipate and avoid.

Animal Damage
Squirrels and raccoons (and roof rats in coastal regions) will sometimes tear through shingles and roof sheathing when they’re searching for a protected area in which to build nests and raise their young. They often attack the roof’s eaves first, especially on homes that have suffered decay to the roof sheathing due to a lack of drip edges or from problems caused by ice damming, because decayed sheathing is softer and easier to tear through.  If you hear any activity of wildlife on your roof, check inside your attic for evidence of pest intrusion, such as damaged insulation, which pests may use for nesting material.  Darkened insulation generally indicates that excess air is blowing through some hole in the structure, leading the insulation to become darkened by dirt or moisture.

Biological Growth 
Algae, moss and lichen are types of biological growth that may be found on asphalt shingles under certain conditions. Some professionals consider this growth destructive, while others consider it merely a cosmetic problem.  Asphalt shingles may become discolored by both algae and moss, which spread by releasing airborne spores.

Almost all biological growth on shingles is related to the long-term presence of excess moisture, which is why these problems are more common in areas with significant rainfall and high relative humidity.  But even in dry climates, roofs that are shaded most of the time can develop biological growth.

What we commonly call “algae” is actually not algae, but a type of bacteria capable of photosynthesis. Algae appears as dark streaks, which are actually the dark sheaths produced by the organisms to protect themselves from the ultraviolet radiation of the sun. When environmental conditions are right, the problem can spread quickly across a roof.

Algae can feed on mineral nutrients, such as the calcium carbonate in limestone used as asphalt shingle filler. Calcium carbonate also causes asphalt to retain moisture, which also promotes algae growth, so shingles with excessive filler may be more likely to suffer more algae growth.  The rate of filler consumption is slow enough that it’s not generally considered a serious problem.

Algae attach to the shingle by secreting a substance that bonds it tightly to the surface. Growth can be difficult to remove without damaging the roof. The best method is prevention. Algae stains can sometimes be lightened in color by using special cleaners.  Power-washing and heavy scrubbing may loosen or dislodge granules. Chemicals used for cleaning shingles may damage landscaping. Also, the cleaning process makes the roof wet and slippery, so such work should be performed by a qualified professional.

Moss is a greenish plant that can grow more thickly than algae. It attaches itself to the roof through a shallow root system that can be freed from shingles fairly easily with a brush.  Moss deteriorates shingles by holding moisture against them, but this is a slow process. Moss is mostly a cosmetic issue and, like algae, can create hazardous conditions for those who climb on the roof.

Lichens are composite organisms consisting of a fungus and a photosynthetic partner, such as green or blue-green algae. Lichens bond tightly to the roof, and when they’re removed from asphalt shingles, they may take granules with them. Damage from lichen removal can resemble blistering.

"Tobacco-juicing" is the brownish discoloration that appears on the surface of shingles, under certain weather conditions. It’s often temporary and may have a couple of different causes. After especially long periods of intensely sunny days, damp nights and no rain, water-soluble compounds may leach out of the asphalt from the shingles and be deposited on the surface.  Tobacco-juicing may also appear under the same weather conditions if the air is especially polluted.  Tobacco-juicing won’t harm asphalt shingles, although it may run down the roof and stain siding. Although it’s more common in the West and Southwest, it can happen anywhere that weather conditions are right.  You can spray-wash or paint the exterior of the home to remove tobacco-juicing.

Your InterNACHI inspector should investigate signs of roof damage or deterioration before you call a roofing contractor.  That way, you’ll know exactly what types of problems should be addressed before you break out the checkbook for repairs.


Attic Insulation

Heating and cooling costs can be slashed by up to 30% per year by properly sealing and insulating the home. Insulating the attic should be a top priority for preventing heat loss because as heat rises, a critical amount of heat loss from the living areas of the home occurs through an unfinished attic.  During the summer months, heat trapped in the attic can reduce the home’s ability to keep cool, forcing the home's cooling system to work overtime.

The lack of adequate ventilation in insulated attics is a common problem.  Ensuring that there is a free flow of outside air from the soffits to the roof vents is key to a well-functioning insulation system. Look behind the baffles to see if there is any misplaced insulation obstructing the natural air flow, and check the roof vents to make sure that outside air is exhausting properly. Also, look for spots where the insulation is compacted; it may need to be fluffed out.  If loose-fill insulation is installed, check for any thinly spread areas that may need topping up. Finally, look for dark spots in the insulation where incoming air is admitting wind-blown dust and moisture into the material.  Any unintended openings or holes caused by weathering or pest damage should be repaired first.

Installing Attic Insulation
The objective in an attic insulation project is to insulate the living space of the house while allowing the roof to retain the same temperature as the outdoors. This prevents cold outside air from traveling through the attic and into the living area of the home. In order to accomplish this, an adequate venting system must be in place to vent the roof by allowing air flow to enter through soffit-intake vents and out through ridge vents, gable vents or louver vents.

If there is currently a floor in the attic, it will be necessary to pull up pieces of the floor to install the insulation. In this case, it will be easier to use a blower and loose-fill insulation to effectively fill the spaces between the joists. If you choose to go with blown-in insulation, you can usually get free use of a blower when you purchase a certain amount of insulation.
 
When installing fiberglass insulation, make sure that you wear personal protective equipment, including a hat, gloves, goggles and a face mask, as stray fiberglass material can become airborne, which can cause irritation to the lungs, eyes and exposed skin.

Before you begin actually installing the insulation, there is some important preparation involved in order to ensure that the insulation is applied properly to prevent hazards and to achieve maximum effectiveness.

Step 1: Install Roof Baffles
In order to maintain the free flow of outside air, it is recommended that polystyrene or plastic roof baffles are installed where the joists meet the rafters. These can be stapled into place.

Step 2: Place Baffles Around Electrical Fixtures
Next, place baffles around any electrical fixtures (lights, electrical receptacles, etc.), since these may become hot while in use. Hold the baffles in place by cross-sectioning the rafters with 2x4s placed at a 3-inch clearance around the fixture.  Cut the polystyrene board to fit around the fixture and inside the wood square you have just created.

Step 3: Install a Vapor Barrier
If you are installing insulation with a vapor barrier, make sure it faces the interior of the house. Another option for a vapor barrier is to take sheets of plastic and lay them between the ceiling joists.  Then, using a staple gun, tack them to the sides of the joists.

Step 4:  Apply the Insulation
Begin by cutting long strips of fiberglass to measure, and lay them in between the joists. Do not bunch or compress the material; this will reduce the insulative effect.
If you’re not planning to put in an attic floor, a second layer of insulation may be laid at a 90-degree angle to the first layer. Do not lay in a second moisture barrier, as moisture could potentially be trapped between the two layers. This second layer of insulation will make it easier to obtain the recommended R-value. In colder climates, an R-value of 49 is recommended for adequate attic insulation. In warmer climates, an R-value of 30 is recommended. Fiberglass insulation has an R-value of roughly R-3 per inch of thickness; cellulose has an R-value of roughly R-4 per inch, but it doesn't retain its R-value rating as well as fiberglass.

If an attic floor is in place, it will be easier to use a blower to add cellulose insulation into the spaces. The best way to achieve this is to carefully select pieces of the floor and remove them in a manner such that you will have access to all of the spaces in between the joists. Run the blower hose up into the attic. A helper may be needed to control the blower. Blow the insulation into the spaces between the joists, taking care not to blow insulation near electrical fixtures. Replace any flooring pieces that were removed.

Loose-fill insulation, either fiberglass or cellulose, is also a good option in cases where there is no attic floor. In such circumstances, you won’t need a blower; you can simply place the insulation between the joists by hand. You may also wish to even out the spread with a notched leveler.


Attic Access Pull-Down Stairs

An attic pull-down ladder, also called an attic pull-down stairway or stairs, is a collapsible ladder that’s permanently attached to the attic floor.  It’s used to access the attic without being required to use a portable ladder, which can be unstable, as well as inconvenient.

Common Defects
It’s typical for the homeowner, rather than the professional builder, to install the attic pull-down stairs, especially if it’s an older home or a newer home that’s been built upward in order to use the attic for living or storage space. That’s why these stairs rarely meet safety standards and are prone to a number of defects.
Some of the more common defective conditions include:
  • cut bottom cord of structural truss.  The homeowner may have cut through a structural member while installing a pull-down ladder, unknowingly weakening the structure. Structural members should not be modified without an engineer’s approval;
  • fastened with improper nails or screws. Drywall or deck screws may be used instead of the standard 16d penny nails or ¼x3-inch lag screws. Nails and screws that are intended for other purposes may have reduced shear strength and may not support the pull-down ladder;
  • fastened with an insufficient number of nails or screws. Manufacturers provide a certain number of nails with instructions that they all be used, and they do this for a good reason;
  • lack of insulation. The attic hatch or door is not likely to be weatherstripped and/or insulated, which will allow air from the attic to flow freely into the living space of the home, and this will cause the heating or cooling system to run overtime. An attic hatch cover box can be installed to increase energy savings;
  • loose mounting bolts, which is typically caused by age, although improper installation will hasten the loosening process;
  • attic pull-down ladders that are cut too short. The stairs should reach the floor; 
  • attic pull-down ladders that are cut too long. This causes pressure at the folding hinge, which can cause breakage;
  • improper or missing fasteners;
  • compromised fire barrier (when the attic and access are above an attached garage);
  • attic ladder frame that is not properly secured to the ceiling opening; and
  • closed ladder that is covered with debris, such as blown insulation or roofing material shed during roof work; a
  • cracked steps. This defect is a problem with wooden ladders.
Safety Tips:
  • If yours is a sliding pull-down ladder, there is a potential for it to slide down too quickly, which can lead to an injury. Always pull the ladder down slowly and cautiously. 
  • Do not allow children to enter the attic unattended. The lanyard attached to the attic stairs should be short enough that children cannot reach it. Parents can also lock the attic ladder so that a key or combination is required to access it.
  • If possible, avoid carrying large loads into the attic. While a properly installed stairway will safely support an adult, it might fail if you’re carrying a very heavy load. Many trips can be made to reduce the total weight load, if possible.
  • Replace an old, rickety wooden ladder with a new one. The newer aluminum models are lightweight, sturdy and easy to install.  If you do install a new ladder, follow the manufacturer’s instructions to the letter, and test the ladder’s operation before actually using it.


Regards,

Jeff L. Gollaher
Full Circle Home Inspections

Friday, February 22, 2013

Garage Door Safety


Garage Door Safety                                           

The garage door is the largest moving object in a house.  Its parts are under high tension.  All repairs and adjustments should be performed by a trained garage door systems technician.  To find a technician, visit theInternational Door Association website.  If the garage door appears inoperable or out of plumb, do not attempt to operate the garage door opener.  If the door appears plumb, you can perform some basic testing to ensure that your garage door is operating as it should.

Photo-Electric Eyes

Federal law states that residential garage door openers manufactured after 1992 must be equipped with photo-electric eyes or some other safety-reverse feature.  If the garage door has an opener, check to see if photo-electric eyes are installed.  They should be near the floor, mounted to the left and right sides of the bottom door panel.  The beam of the photo-electric eyes should not be higher than 6 inches above the floor.
 

Non-Contact Reversal Test 

This check applies to door systems that are equipped with photo-electric eyes.  Standing inside the garage and safely away from the path of the door, use the remote control or wall button to close the door.  As the door is closing, wave an object in the path of the photo-electric eye beam. The door should immediately reverse and return to the fully-open position.

Contact Reversal Test 

This check applies to doors with openers when the opener’s force setting has been properly set, and when the opener reinforcement bracket is securely and appropriately attached to the door’s top section.  If you’re concerned that a contact reversal test may cause damage to the garage door or its components, don’t do it.
 
Otherwise, begin this test with the door fully open.  Under the center of the door, place a 2x4 piece of wood flat on the floor in the path of the door.  Standing inside the garage but safely away from the path of the door, use the wall push button to close the door.  When the door contacts the wood, the door should automatically reverse direction and return to the fully-open position.
 
If your garage door fails or is slow to respond to any of these tests, contact a qualified technician who can check for any necessary repairs or upgrades.
 
Regards,

Jeff L. Gollaher
Full Circle Home Inspections